Footswitch – Bluetooth / wired, Fiber – radial, bare, conical fiber available
Dual Wavelength:
We are India’s most technologically advanced Diode Laser manufacturers.
Using 980nm a classical wavelength where the absorption coefficient is higher in pigmentation as compared to 1470nm whereas 1470 nm works extremely well in presence of water.
With higher affinity in water with 1470nm power required will be less, so the energy delivered will be also less.
This Dual combination provides the highest cutting efficiency, Good coagulation, and shrinkage.
This Dual wavelength offers Surgeons to choose the wavelength to be used either on an individual basis or in combination.
This dual wavelength can be used for precise incision, excision, vaporization, and cutting.
Advantages- Trident-P:
Laser type – Diode Laser
Model – IMD 20 W
Wavelength – 980nm (10W) & 1470nm ( 10W)
Power – 0.5 to 20 W
Operation Mode – CW/ Single / Pulse
Repetition Rate – 20,000 HZ
Delivery system – Bare, Radial, Conical (600 microns), Footswitch – Bluetooth / wired
Aiming beam – 660nm / 5mW
Weight – 3.5 kg
Indication - Proctology & Beyond:
This Laser is highly useful for various indications as mentioned below-
Cosmetic gynecology – Laser vaginal Rejuvenation ( separate handpiece has to be purchased).
Spider vein Treatment – (Handpiece has to be purchased.
Lipolysis – attachments have to be purchased.
Physiotherapy
Spine treatment – PLDD
ENT – for all deep laryngeal surgery, turbinate reduction, and many more.
Circumcision
Trident - P 10 W(980nm) + 10W(1470nm)
Specification:
Maximum Power
10W + 10 W
Wavelength
1470nm(10W) & 980nm (10W)
Mode
CW/Pulse
Surgical Handpiece
2
Aiming beam
650nm
interlock key
1
Footswitch
Bluetooth/Wire
Software
M
Dual wavelength with multipurpose use
The highest model where cutting coagulation and shrinkage can be actively achieved
Laser Treatment in Proctology:
Hemorrhoids - Laser energy is being delivered over the tissue followed by delivery of energy into pile mass. This procedure is performed mostly under local anesthesia and the patient can be discharged on the same day. No cut is required in complete treatment.
Anal fissure - Lateral sphincterotomy is performed by giving an incision in the sphincter muscle via laser fiber. This helps release the tension of the fissure and allows the affected area to heal.
Anal fistula - Closure of fistula track by delivering laser energy by radial fiber. Laser energy delivered via radial fiber help in tissue shrinkage which closes the track.
Pilonidal sinus- removal of debris, inflammatory tissue, and hairs from the tract with minimal collateral tissue damage.
EVLT:
- Varicose vein treatment is done via laser for twisted, inflamed or wide veins situated under the skin.
- Radial fiber helps in swelling or inflammation because of the heat transferred from the laser
Additional Indications:
Liposuction
LVR( Vaginal Rejuvenation)
PLDD(Percutaneous Laser Disc Decompression
Fibers:
Bare fiber:
- Used for cutting & Coagulation
- 400 & 600-micron fiber thickness available
- SMA 905A Connector
- Used for all the machine
- Used in Piles & Fissure
- Sterilized by using ethylene oxide
Radial Fiber:
- Non-cutting tip
- 600-micron thickness
- SMA 905A Connector
- Indicated in Fistula & Varicose vein
- Sterilized by using ethylene oxide
Conical fiber:
- Only used for piles treatment
- SMA 905A Connector
- Sterilized by ethylene oxide
- 600-micron thickness
Accessories
Handpiece - Straight & curved handpieces are given along with the machine
Footswitch – Bluetooth / wired, Fiber – radial, bare, conical fiber available
Dual Wavelength:
We are India’s most technologically advanced Diode Laser manufacturers.
Using 980nm a classical wavelength where the absorption coefficient is higher in pigmentation as compared to 1470nm whereas 1470 nm works extremely well in presence of water.
With higher affinity in water with 1470nm power required will be less, so the energy delivered will be also less.
This Dual combination provides the highest cutting efficiency, Good coagulation, and shrinkage.
This Dual wavelength offers Surgeons to choose the wavelength to be used either on an individual basis or in combination.
This dual wavelength can be used for precise incision, excision, vaporization, and cutting.
Advantages- Trident-P:
Laser type – Diode Laser
Model – IMD 20 W
Wavelength – 980nm (10W) & 1470nm ( 10W)
Power – 0.5 to 20 W
Operation Mode – CW/ Single / Pulse
Repetition Rate – 20,000 HZ
Delivery system – Bare, Radial, Conical (600 microns), Footswitch – Bluetooth / wired
Aiming beam – 660nm / 5mW
Weight – 3.5 kg
Indication - Proctology & Beyond:
This Laser is highly useful for various indications as mentioned below-
Cosmetic gynecology – Laser vaginal Rejuvenation ( separate handpiece has to be purchased).
Spider vein Treatment – (Handpiece has to be purchased.
Lipolysis – attachments have to be purchased.
Physiotherapy
Spine treatment – PLDD
ENT – for all deep laryngeal surgery, turbinate reduction, and many more.
Circumcision
Trident - P 10 W(980nm) + 10W(1470nm)
Specification:
Maximum Power
10W + 10 W
Wavelength
1470nm(10W) & 980nm (10W)
Mode
CW/Pulse
Surgical Handpiece
2
Aiming beam
650nm
interlock key
1
Footswitch
Bluetooth/Wire
Software
M
Dual wavelength with multipurpose use
The highest model where cutting coagulation and shrinkage can be actively achieved
Laser Treatment in Proctology:
Hemorrhoids - Laser energy is being delivered over the tissue followed by delivery of energy into pile mass. This procedure is performed mostly under local anesthesia and the patient can be discharged on the same day. No cut is required in complete treatment.
Anal fissure - Lateral sphincterotomy is performed by giving an incision in the sphincter muscle via laser fiber. This helps release the tension of the fissure and allows the affected area to heal.
Anal fistula - Closure of fistula track by delivering laser energy by radial fiber. Laser energy delivered via radial fiber help in tissue shrinkage which closes the track.
Pilonidal sinus- removal of debris, inflammatory tissue, and hairs from the tract with minimal collateral tissue damage.
EVLT:
- Varicose vein treatment is done via laser for twisted, inflamed or wide veins situated under the skin.
- Radial fiber helps in swelling or inflammation because of the heat transferred from the laser
Additional Indications:
Liposuction
LVR( Vaginal Rejuvenation)
PLDD(Percutaneous Laser Disc Decompression
Fibers:
Bare fiber:
- Used for cutting & Coagulation
- 400 & 600-micron fiber thickness available
- SMA 905A Connector
- Used for all the machine
- Used in Piles & Fissure
- Sterilized by using ethylene oxide
Radial Fiber:
- Non-cutting tip
- 600-micron thickness
- SMA 905A Connector
- Indicated in Fistula & Varicose vein
- Sterilized by using ethylene oxide
Conical fiber:
- Only used for piles treatment
- SMA 905A Connector
- Sterilized by ethylene oxide
- 600-micron thickness
Accessories
Handpiece - Straight & curved handpieces are given along with the machine