AWS-401 Anesthesia Workstation

AWS-401 Anesthesia Workstation

AWS-401 Anesthesia Workstation

Brand :
ACCURA
Seller :
Out of stock
Features
British Standard (02, N20, AIR)
10.4” TFT LCD screen
Built-in Anesthesia Ventilator
Continuous F102 monitoring
Compact C02 absorber (autoclavable)
Provision for Two vaporizers
High precise vaporizer (Isoflurane I Sevoflurane I Enflurance I Halothane)
Yoke system for 5L cylinders
Selectable mounting vaporizer system

Anesthesia Worksation

  • > British Standard (02, N20, AIR)
  • > 10.4” TFT LCD screen
  • > Built-in Anesthesia Ventilator
  • > Continuous F102 monitoring
  • > Compact C02 absorber (autoclavable)
  • > Provision for Two vaporizers
  • > High precise vaporizer (Isoflurane I Sevoflurane I Enflurance I Halothane)
  • > Yoke system for 5L cylinders
  • > Selectable mounting vaporizer system
  • Anesthesia main unit:
  • • High resolution 10.4” colour TFT LCD screen
  • • Dual-end pressure flow sensor, The unit can monitor Tidal Volume, Respiratory frequency, airway pressure, pressure wave, flow wave (two-way), High Pressure limitation, Low Pressure limitation, Apnoea, Oxygen concentration under both two operating mode (Auto/Manual)
  • • Respiration loop function (Optional: scavenging system)
  • • Close, semi-close, semi-open system
  • Application : Adult, Paediatric
  • • Low gas alarming : Alarming will be for more than 7 seconds.
  • • High pressure limitation: whenever airway pressure exceeds the pre-set
  • • High pressure, ventilator offers protection automatically, for the safety of the patient.
  • • Low pressure protection : Once O2 pressure less than 0.1MPa, N20 gas supply stops automatically.
  • • Power failure alarm - automatically machine runs on USP
  • • 02 flush : 35 ~ 75 L/min
  • • Gas Pressure : O2 : 0.27~0.55 MPa, N20 : 0.27~0.55 MPa, AIR: 0.27~0.55 MPa
  • • Power : 220V±10%, 50Hz±1%; Backup USP Battery.
  • • Yoke system for O2 & N2O - 5 Ltr. Cylinders
  • Flow meter:
  • • O2, N2O, AIR - six tubes (0~10 L/min)
  • • O2/N2O inter-lock system, to keep O2 concentration not less than 25%
  • Anesthesia Ventilator (Air/O2 inter-link system):
  • • Adult, Paediatric bellows - 1 set each
  • • Pneumatic driven electric control
  •  Monitor Parameters : Tidal volume, Respiratory frequency, I:E rate, Peak airway pressure, airway pressure waves etc.
  • Working mode: Manual, Auto (IPPV, SIGH, SIMV/F/2, SIPPV, Optional ETCO2) 
  • Tidal volume : 0 ~ 1500 mL
  •  Respiratory frequency : 4 ~ 60 bpm
  •  I:E : 1:0.5 ~ 1:4 adjustable
  • Synchronizer trigger Pressure : -1 ~ 0K Pa
  • High pressure limitation : 2 ~ 6 KPa 
  • Low pressure limitation : O.6 ~ 2 KPa
  • Respiratory Circuit:
  • • Consolidated compact CO2 absorber (autoclavable)
  • Vaporizer:
  • • High precise vaporizer (Enflurane/Halothane/Isoflurane/Sevoflurane)
  • • Adjustable range : 0.5~5% VOL
  • • Automatic compensation function — flow, pressure, temperature
  • • Self-lock & inter-lock function
  • • Volume : 280 ml (Optional: 250 ml Penlon)
Share Your Requirements With Us