AWS-401 Anesthesia Workstation
Seller : M.S.ENTERPRISES
Brand : ACCURA
Manufacturer : M.S.Enterprises
Out of stock
FeaturesBritish Standard (02, N20, AIR)
10.4” TFT LCD screen
Built-in Anesthesia Ventilator
Continuous F102 monitoring
Compact C02 absorber (autoclavable)
Provision for Two vaporizers
High precise vaporizer (Isoflurane I Sevoflurane I Enflurance I Halothane)
Yoke system for 5L cylinders
Selectable mounting vaporizer system
10.4” TFT LCD screen
Built-in Anesthesia Ventilator
Continuous F102 monitoring
Compact C02 absorber (autoclavable)
Provision for Two vaporizers
High precise vaporizer (Isoflurane I Sevoflurane I Enflurance I Halothane)
Yoke system for 5L cylinders
Selectable mounting vaporizer system
Description
Anesthesia Worksation
- > British Standard (02, N20, AIR)
- > 10.4” TFT LCD screen
- > Built-in Anesthesia Ventilator
- > Continuous F102 monitoring
- > Compact C02 absorber (autoclavable)
- > Provision for Two vaporizers
- > High precise vaporizer (Isoflurane I Sevoflurane I Enflurance I Halothane)
- > Yoke system for 5L cylinders
- > Selectable mounting vaporizer system
- Anesthesia main unit:
- • High resolution 10.4” colour TFT LCD screen
- • Dual-end pressure flow sensor, The unit can monitor Tidal Volume, Respiratory frequency, airway pressure, pressure wave, flow wave (two-way), High Pressure limitation, Low Pressure limitation, Apnoea, Oxygen concentration under both two operating mode (Auto/Manual)
- • Respiration loop function (Optional: scavenging system)
- • Close, semi-close, semi-open system
- Application : Adult, Paediatric
- • Low gas alarming : Alarming will be for more than 7 seconds.
- • High pressure limitation: whenever airway pressure exceeds the pre-set
- • High pressure, ventilator offers protection automatically, for the safety of the patient.
- • Low pressure protection : Once O2 pressure less than 0.1MPa, N20 gas supply stops automatically.
- • Power failure alarm - automatically machine runs on USP
- • 02 flush : 35 ~ 75 L/min
- • Gas Pressure : O2 : 0.27~0.55 MPa, N20 : 0.27~0.55 MPa, AIR: 0.27~0.55 MPa
- • Power : 220V±10%, 50Hz±1%; Backup USP Battery.
- • Yoke system for O2 & N2O - 5 Ltr. Cylinders
- Flow meter:
- • O2, N2O, AIR - six tubes (0~10 L/min)
- • O2/N2O inter-lock system, to keep O2 concentration not less than 25%
- Anesthesia Ventilator (Air/O2 inter-link system):
- • Adult, Paediatric bellows - 1 set each
- • Pneumatic driven electric control
- Monitor Parameters : Tidal volume, Respiratory frequency, I:E rate, Peak airway pressure, airway pressure waves etc.
- Working mode: Manual, Auto (IPPV, SIGH, SIMV/F/2, SIPPV, Optional ETCO2)
- Tidal volume : 0 ~ 1500 mL
- Respiratory frequency : 4 ~ 60 bpm
- I:E : 1:0.5 ~ 1:4 adjustable
- Synchronizer trigger Pressure : -1 ~ 0K Pa
- High pressure limitation : 2 ~ 6 KPa
- Low pressure limitation : O.6 ~ 2 KPa
- Respiratory Circuit:
- • Consolidated compact CO2 absorber (autoclavable)
- Vaporizer:
- • High precise vaporizer (Enflurane/Halothane/Isoflurane/Sevoflurane)
- • Adjustable range : 0.5~5% VOL
- • Automatic compensation function — flow, pressure, temperature
- • Self-lock & inter-lock function
- • Volume : 280 ml (Optional: 250 ml Penlon)
FeaturesBritish Standard (02, N20, AIR)
10.4” TFT LCD screen
Built-in Anesthesia Ventilator
Continuous F102 monitoring
Compact C02 absorber (autoclavable)
Provision for Two vaporizers
High precise vaporizer (Isoflurane I Sevoflurane I Enflurance I Halothane)
Yoke system for 5L cylinders
Selectable mounting vaporizer system
10.4” TFT LCD screen
Built-in Anesthesia Ventilator
Continuous F102 monitoring
Compact C02 absorber (autoclavable)
Provision for Two vaporizers
High precise vaporizer (Isoflurane I Sevoflurane I Enflurance I Halothane)
Yoke system for 5L cylinders
Selectable mounting vaporizer system
Description
Anesthesia Worksation
- > British Standard (02, N20, AIR)
- > 10.4” TFT LCD screen
- > Built-in Anesthesia Ventilator
- > Continuous F102 monitoring
- > Compact C02 absorber (autoclavable)
- > Provision for Two vaporizers
- > High precise vaporizer (Isoflurane I Sevoflurane I Enflurance I Halothane)
- > Yoke system for 5L cylinders
- > Selectable mounting vaporizer system
- Anesthesia main unit:
- • High resolution 10.4” colour TFT LCD screen
- • Dual-end pressure flow sensor, The unit can monitor Tidal Volume, Respiratory frequency, airway pressure, pressure wave, flow wave (two-way), High Pressure limitation, Low Pressure limitation, Apnoea, Oxygen concentration under both two operating mode (Auto/Manual)
- • Respiration loop function (Optional: scavenging system)
- • Close, semi-close, semi-open system
- Application : Adult, Paediatric
- • Low gas alarming : Alarming will be for more than 7 seconds.
- • High pressure limitation: whenever airway pressure exceeds the pre-set
- • High pressure, ventilator offers protection automatically, for the safety of the patient.
- • Low pressure protection : Once O2 pressure less than 0.1MPa, N20 gas supply stops automatically.
- • Power failure alarm - automatically machine runs on USP
- • 02 flush : 35 ~ 75 L/min
- • Gas Pressure : O2 : 0.27~0.55 MPa, N20 : 0.27~0.55 MPa, AIR: 0.27~0.55 MPa
- • Power : 220V±10%, 50Hz±1%; Backup USP Battery.
- • Yoke system for O2 & N2O - 5 Ltr. Cylinders
- Flow meter:
- • O2, N2O, AIR - six tubes (0~10 L/min)
- • O2/N2O inter-lock system, to keep O2 concentration not less than 25%
- Anesthesia Ventilator (Air/O2 inter-link system):
- • Adult, Paediatric bellows - 1 set each
- • Pneumatic driven electric control
- Monitor Parameters : Tidal volume, Respiratory frequency, I:E rate, Peak airway pressure, airway pressure waves etc.
- Working mode: Manual, Auto (IPPV, SIGH, SIMV/F/2, SIPPV, Optional ETCO2)
- Tidal volume : 0 ~ 1500 mL
- Respiratory frequency : 4 ~ 60 bpm
- I:E : 1:0.5 ~ 1:4 adjustable
- Synchronizer trigger Pressure : -1 ~ 0K Pa
- High pressure limitation : 2 ~ 6 KPa
- Low pressure limitation : O.6 ~ 2 KPa
- Respiratory Circuit:
- • Consolidated compact CO2 absorber (autoclavable)
- Vaporizer:
- • High precise vaporizer (Enflurane/Halothane/Isoflurane/Sevoflurane)
- • Adjustable range : 0.5~5% VOL
- • Automatic compensation function — flow, pressure, temperature
- • Self-lock & inter-lock function
- • Volume : 280 ml (Optional: 250 ml Penlon)
FeaturesBritish Standard (02, N20, AIR)
10.4” TFT LCD screen
Built-in Anesthesia Ventilator
Continuous F102 monitoring
Compact C02 absorber (autoclavable)
Provision for Two vaporizers
High precise vaporizer (Isoflurane I Sevoflurane I Enflurance I Halothane)
Yoke system for 5L cylinders
Selectable mounting vaporizer system
10.4” TFT LCD screen
Built-in Anesthesia Ventilator
Continuous F102 monitoring
Compact C02 absorber (autoclavable)
Provision for Two vaporizers
High precise vaporizer (Isoflurane I Sevoflurane I Enflurance I Halothane)
Yoke system for 5L cylinders
Selectable mounting vaporizer system
Description
Anesthesia Worksation
- > British Standard (02, N20, AIR)
- > 10.4” TFT LCD screen
- > Built-in Anesthesia Ventilator
- > Continuous F102 monitoring
- > Compact C02 absorber (autoclavable)
- > Provision for Two vaporizers
- > High precise vaporizer (Isoflurane I Sevoflurane I Enflurance I Halothane)
- > Yoke system for 5L cylinders
- > Selectable mounting vaporizer system
- Anesthesia main unit:
- • High resolution 10.4” colour TFT LCD screen
- • Dual-end pressure flow sensor, The unit can monitor Tidal Volume, Respiratory frequency, airway pressure, pressure wave, flow wave (two-way), High Pressure limitation, Low Pressure limitation, Apnoea, Oxygen concentration under both two operating mode (Auto/Manual)
- • Respiration loop function (Optional: scavenging system)
- • Close, semi-close, semi-open system
- Application : Adult, Paediatric
- • Low gas alarming : Alarming will be for more than 7 seconds.
- • High pressure limitation: whenever airway pressure exceeds the pre-set
- • High pressure, ventilator offers protection automatically, for the safety of the patient.
- • Low pressure protection : Once O2 pressure less than 0.1MPa, N20 gas supply stops automatically.
- • Power failure alarm - automatically machine runs on USP
- • 02 flush : 35 ~ 75 L/min
- • Gas Pressure : O2 : 0.27~0.55 MPa, N20 : 0.27~0.55 MPa, AIR: 0.27~0.55 MPa
- • Power : 220V±10%, 50Hz±1%; Backup USP Battery.
- • Yoke system for O2 & N2O - 5 Ltr. Cylinders
- Flow meter:
- • O2, N2O, AIR - six tubes (0~10 L/min)
- • O2/N2O inter-lock system, to keep O2 concentration not less than 25%
- Anesthesia Ventilator (Air/O2 inter-link system):
- • Adult, Paediatric bellows - 1 set each
- • Pneumatic driven electric control
- Monitor Parameters : Tidal volume, Respiratory frequency, I:E rate, Peak airway pressure, airway pressure waves etc.
- Working mode: Manual, Auto (IPPV, SIGH, SIMV/F/2, SIPPV, Optional ETCO2)
- Tidal volume : 0 ~ 1500 mL
- Respiratory frequency : 4 ~ 60 bpm
- I:E : 1:0.5 ~ 1:4 adjustable
- Synchronizer trigger Pressure : -1 ~ 0K Pa
- High pressure limitation : 2 ~ 6 KPa
- Low pressure limitation : O.6 ~ 2 KPa
- Respiratory Circuit:
- • Consolidated compact CO2 absorber (autoclavable)
- Vaporizer:
- • High precise vaporizer (Enflurane/Halothane/Isoflurane/Sevoflurane)
- • Adjustable range : 0.5~5% VOL
- • Automatic compensation function — flow, pressure, temperature
- • Self-lock & inter-lock function
- • Volume : 280 ml (Optional: 250 ml Penlon)
SKU | AWS-401 |
---|---|
Country of Manufacture | China |
Usage/Application | Anesthesia |
Package Dimension (LxBxH in cms) | 150X80x75 |
Request for Quote | Yes |
Manufacturer | M.S.Enterprises |
Warranty | 1 year |
Return/Buy Back policy | N/A |
Write Your Own Review